FANUC Alarm FRCE-159 — F/S sensor limit overflow (F:%d^1)
FANUC FRCE-159 (“F/S sensor limit overflow (F:%d^1)”): An excessive load was put on the sensor head. First check: 1. Make sure that the value of 'Insert Force' in 'Basic Data' is not too large.
Updated 2026-08-29 · LogrobotLM reference
Description
An excessive load was put on the sensor head.
Remedy · Remède
1. Make sure that the value of 'Insert Force' in 'Basic Data' is not too large. If not, go to the next step. 2. Bad impedance parameters can cause vibration during force control. Increase the Mass value in the impedance parameters.
Frequently asked · Questions fréquentes
- What does FANUC alarm FRCE-159 mean?
- FANUC FRCE-159 (“F/S sensor limit overflow (F:%d^1)”): An excessive load was put on the sensor head.
- How do you troubleshoot FANUC alarm FRCE-159?
- 1. Make sure that the value of 'Insert Force' in 'Basic Data' is not too large. If not, go to the next step. 2. Bad impedance parameters can cause vibration during force control. Increase the Mass value in the impedance parameters.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →