FANUC Alarm FRCE-171 — F/S output data frozen (F:…)

Manufacturer wording — F/S output data frozen (F:%d^1)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC FRCE-171 (“F/S output data frozen (F:…)”): The output data from the sensor head is frozen (unchanging). First check: 1. Check the force sensor output data on TP (Force sensor status screen). Likely part: Sensor board (Sensor interface board).

Updated 2026-09-17 · LogrobotLM reference

Description

The output data from the sensor head is frozen (unchanging).

Remedy

1. Check the force sensor output data on TP (Force sensor status screen). The value must vary slightly over time due to sensor background noise. If the value is constant, it is frozen; go to the next step. 2. Check the sensor cable connectivity. Check also for cut lines. If there is nothing wrong, go to the next step. 3. Replace the sensor board. If this

Part to check / replace

FANUC FRCE-171 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.