LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm FRCE-180 — F/S ITP counter error (F:…)

Manufacturer wording — F/S ITP counter error (F:%d^1)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC FRCE-180 (“F/S ITP counter error (F:…)”): Communication failed between the sensor board and the force sensor. First check: 1. Move the robot to a safe pose. Likely part: Sensor board (Sensor interface board) +1 more.

Updated 2026-09-17 · LogrobotLM reference

Description

Communication failed between the sensor board and the force sensor.

Remedy

1. Move the robot to a safe pose. 2. Turn the controller OFF, then ON again. If this alarm occurs again, go to the next step. 3. Check the sensor cable connectivity. Check also for cut lines. If there is nothing wrong, go to the next step. 4. Replace the sensor board. If this alarm occurs again, go to the next step. 5. Replace the sensor head.

Part to check / replace

FANUC FRCE-180 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Same hardware involved

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →