FANUC Alarm FRCE-180 — F/S ITP counter error (F:%d^1)
FANUC FRCE-180 (“F/S ITP counter error (F:%d^1)”): Communication failed between the sensor board and the force sensor. First check: 1. Move the robot to a safe pose. Likely part: Sensor board (Sensor interface board) +1 more.
Updated 2026-08-29 · LogrobotLM reference
Description
Communication failed between the sensor board and the force sensor.
Remedy · Remède
1. Move the robot to a safe pose. 2. Turn the controller OFF, then ON again. If this alarm occurs again, go to the next step. 3. Check the sensor cable connectivity. Check also for cut lines. If there is nothing wrong, go to the next step. 4. Replace the sensor board. If this alarm occurs again, go to the next step. 5. Replace the sensor head.
Part to check / replace · Pièce à contrôler / remplacer
FANUC FRCE-180 points to the hardware below — start here before ordering. · FRCE-180 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does FANUC alarm FRCE-180 mean?
- FANUC FRCE-180 (“F/S ITP counter error (F:%d^1)”): Communication failed between the sensor board and the force sensor.
- How do you troubleshoot FANUC alarm FRCE-180?
- 1. Move the robot to a safe pose. 2. Turn the controller OFF, then ON again. If this alarm occurs again, go to the next step. 3. Check the sensor cable connectivity. Check also for cut lines. If there is nothing wrong, go to the next step. 4. Replace the sensor board. If this alarm occurs again, go to the next step.…
- Which part is involved in FANUC FRCE-180?
- FRCE-180 points to Sensor board (Sensor interface board), Sensor head (Sensor head). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Same hardware involved / Même matériel en cause
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →