FANUC Alarm INTP-376 — ABORT Motion in ISR failed
Manufacturer wording — ABORT (%s^4, %d^5) Motion in ISR failed
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC INTP-376 (“ABORT Motion in ISR failed”): A MOVE statement was executed in an interrupt routine while a motion in the interrupted program was still in progress. First check: One (or both) of the following should correct this problem: 1.
Updated 2026-09-17 · LogrobotLM reference
Description
A MOVE statement was executed in an interrupt routine while a motion in the interrupted program was still in progress.
Remedy
One (or both) of the following should correct this problem: 1. Add CANCEL or STOP condition handler action before the call to the interrupt routine in the condition handler. 2. Add a DELAY 500 statement before the first move in the interrupt routine to allow the motion to complete.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →