FANUC Alarm MEMO-103 — WARN Check sum error occurred
Warning- Hardware
- main board and memory
- Controllers
- R-J3iB / R-30iA
- FANUC class
- WARN
FANUC MEMO-103 (“WARN Check sum error occurred”): The specified data was broken. First check: Perform a cold start: 1.
Updated 2026-10-22 · LogrobotLM reference
Description
The specified data was broken. This is the internal error.
Remedy
Perform a cold start: 1. Turn off the robot. 2. On the teach pendant, press and hold the SHIFT and RESET keys. 3. While still pressing the SHIFT and RESET keys, turn on the robot. If the error is not cleared, document the events that led to the error and call your FANUC Robotics technical representative.
Field diagnosis
The designated data is corrupted: internal checksum error.
What to check
- Cold start (SHIFT + RESET at power-up).
- If the error persists, document it and contact support.
- Note: With SYST-035 in the history, the main board battery is the cause.