FANUC Alarm SYST-031 — SYSTEM F-ROM parity
Error- Hardware
- main board and memory
- Controllers
- R-J3iB / R-30iA
- FANUC class
- SYSTEM
FANUC SYST-031 (“SYSTEM F-ROM parity”): An error has occurred accessing F-ROM First check: Perform a cold start: 1.
Updated 2026-10-22 · LogrobotLM reference
Description
An error has occurred accessing F-ROM
Remedy
Perform a cold start: 1. Turn off the robot. 2. On the teach pendant, press and hold the SHIFT and RESET keys. 3. While still pressing the SHIFT and RESET keys, turn on the robot. If the error is not cleared, document the events that led to the error and call your FANUC Robotics technical representative.
Field diagnosis
Error detected when accessing the F-ROM flash memory.
What to check
- Cold start (SHIFT + RESET held at power-up).
- If the error persists, document it and call support: the main board or its memory module is at fault.
- Note: Back up everything that is still readable before the Cold start.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →