FANUC Alarm MEMO-148 — WARN Flash File access error(read)
Warning- Hardware
- main board and memory
- Controllers
- R-J3iB / R-30iA
- FANUC class
- WARN
FANUC MEMO-148 (“WARN Flash File access error(read)”): The read access to the Flash File(F-ROM) failed. First check: The Flash File(F-ROM) may be broken.
Updated 2026-10-22 · LogrobotLM reference
Description
The read access to the Flash File(F-ROM) failed. Some program may be lost.
Remedy
The Flash File(F-ROM) may be broken. Create or load the lost program again.
Field diagnosis
Reading the flash memory failed: a program may be lost.
What to check
- Recreate or reload the program; replace the main board or the memory module if the code returns.
- Note: Same family as MEMO-147.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →