FANUC Alarm MEMO-149 — WARN Specified program is broken
Warning- Hardware
- main board and memory
- Controllers
- R-J3iB / R-30iA
- FANUC class
- WARN
FANUC MEMO-149 (“WARN Specified program is broken”): Program data has been broken. First check: Please power off and on.
Updated 2026-10-22 · LogrobotLM reference
Description
Program data has been broken.
Remedy
Please power off and on. Then check the program data of the specified program.
Field diagnosis
The data of the designated program is corrupted.
What to check
- Switch the power off and back on, then check the program; reload it from a backup.
- Note: Often linked to a low battery or an aging flash memory.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →