FANUC Alarm PAIN-263WARN Non-decreasing canister position

Description

If the gun has been on for the amount of time specified as Canister Check Time and the amount of change in cylinder position counts has not reached the Minimum Canister Change Counts, this alarm will post. This can be d by low flow rates, where it takes longer to see this minimum cylinder position change. Could be an indicator of trouble with the linear potentiometer or the feedback circuit. : Lower the Minimum Canister Change Counts or increase the Canister Check Time. Check the feedback from the linear potentiometer or repair the low voltage wire for the canister feedback circuit.

Remedy · Remède

N/A

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.