LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm PAIN-383 — WARN Recip zone header error/missing

FANUC PAIN-383 (“WARN Recip zone header error/missing”): This TPE program does not have zone data. First check: Create a new job.

Updated 2026-09-17 · LogrobotLM reference

Description

This TPE program does not have zone data. This job was probably not created using the job generation screen.

Remedy

Create a new job.

Related codes