FANUC Alarm PAIN-438WARN %sCal. time out at max. flow

FANUC PAIN-438 (“WARN %sCal. time out at max. flow”): Accuflow timed out trying to reach the maximum flow rate. First check: Possibly decrease the Gain modifier used for the color. Likely part: Fluid regulator (Fluid regulator).

Updated 2026-08-29 · LogrobotLM reference

Description

Accuflow timed out trying to reach the maximum flow rate. Possible s are: a high gain, a sticking I/P transducer, a bad fluid regulator or frequent fluid pressure changes.

Remedy · Remède

Possibly decrease the Gain modifier used for the color. Retry the calibration. Check and change the transducer if necessary , replace the fluid regulator or service the surge suppression system on the fluid supply pump. The calibration timeout parameter can be increased.

Part to check / replace · Pièce à contrôler / remplacer

FANUC PAIN-438 points to the hardware below — start here before ordering. · PAIN-438 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does FANUC alarm PAIN-438 mean?
FANUC PAIN-438 (“WARN %sCal. time out at max. flow”): Accuflow timed out trying to reach the maximum flow rate. Possible s are: a high gain, a sticking I/P transducer, a bad fluid regulator or frequent fluid pressure changes.
How do you troubleshoot FANUC alarm PAIN-438?
Possibly decrease the Gain modifier used for the color. Retry the calibration. Check and change the transducer if necessary , replace the fluid regulator or service the surge suppression system on the fluid supply pump. The calibration timeout parameter can be increased.
Which part is involved in FANUC PAIN-438?
PAIN-438 points to Fluid regulator (Fluid regulator). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Same hardware involved / Même matériel en cause

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →