LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

FANUC Alarm PAIN-466WARN Pump 1 OUT high pressure warning

Description

Pump #1 outlet pressure has been above the high warning limit for a user configurable period of time. This condition is usually d by one or more of the following: 1. The high pressure warn limit is set too low. 2. The high pressure sensitivity is set too short. 3. The pump start/stop anticipates not setup correctly. 4. Obstructed line, trigger or check valve. 5. The pilot line to mix resin valve is removed or broken. 6. The mix resin valve has failed. 7. The resin outlet transducer has failed.

Remedy · Remède

Make sure the high pressure warning limit is appropriate. Make sure the high pressure

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.