FANUC Alarm PAIN-467 — PAUS Pump 1 OUT high pressure fault
FANUC PAIN-467 (“PAUS Pump 1 OUT high pressure fault”): Pump #1 outlet pressure has been above the high fault limit for a user configurable period of time. First check: Make sure the high pressure fault limit is appropriate.
Updated 2026-08-29 · LogrobotLM reference
Description
Pump #1 outlet pressure has been above the high fault limit for a user configurable period of time. This condition is usually d by one or more of the following: 1. The high pressure fault limit is set too low. 2. The high pressure sensitivity is set too short. 3. The pump start/stop anticipates not setup correctly. 4. Obstructed line, trigger or check valve. 5. The pilot line to mix resin valve is removed or broken. 6. The mix resin valve has failed. 7. The resin outlet transducer has failed.
Remedy · Remède
Make sure the high pressure fault limit is appropriate. Make sure the high pressure sensitivity is appropriate. Make sure the pump start/stop anticipates are appropriate. Make sure the lines, trigger or check valve are not obstructed. Check the pilot line to mix resin valve. Verify that the mix resin valve is not faulty. Check the resin outlet transducer as follows: Through the Analog I/O menu verify the transducer is spanning from near 200 cnts (0 psi) to 600+ cnts (50-80 psi) during a color change cycle .
Frequently asked · Questions fréquentes
- What does FANUC alarm PAIN-467 mean?
- FANUC PAIN-467 (“PAUS Pump 1 OUT high pressure fault”): Pump #1 outlet pressure has been above the high fault limit for a user configurable period of time. This condition is usually d by one or more of the following: 1. The high pressure fault limit is set too low. 2. The high pressure sensitivity is set too short.…
- How do you troubleshoot FANUC alarm PAIN-467?
- Make sure the high pressure fault limit is appropriate. Make sure the high pressure sensitivity is appropriate. Make sure the pump start/stop anticipates are appropriate. Make sure the lines, trigger or check valve are not obstructed. Check the pilot line to mix resin valve. Verify that the mix resin valve is not…
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →