FANUC Alarm PAIN-492 — WARN Pump 2 motor servo not ready
FANUC PAIN-492 (“WARN Pump 2 motor servo not ready”): The servo power to pump #2 is not ready. First check: Usually, the servo not ready occurs when servo power is turned off for some reason, such as E-stop condition, and/or machine locked.
Updated 2026-09-17 · LogrobotLM reference
Description
The servo power to pump #2 is not ready.
Remedy
Usually, the servo not ready occurs when servo power is turned off for some reason, such as E-stop condition, and/or machine locked. Correct the condition and reset the controller.