FANUC Alarm PAIN-493 — WARN Pump 2 totals differ > tolerance
FANUC PAIN-493 (“WARN Pump 2 totals differ > tolerance”): The actual total flow out of pump #2 as measured by the fluid flow meter has a value that is different than the commanded total flow. First check: Do a fluid flow test on pump #2 with a beaker and verify that the beaker amount matches the pump #2 size (cc/rev).
Updated 2026-09-17 · LogrobotLM reference
Description
The actual total flow out of pump #2 as measured by the fluid flow meter has a value that is different than the commanded total flow. This difference is larger than the total flow tolerance.
Remedy
Do a fluid flow test on pump #2 with a beaker and verify that the beaker amount matches the pump #2 size (cc/rev). Verify that the correct KFT factor has been entered for the flow meter per the manufacturers specification. Check the operation of the inlet regulator to verify that no (blow by) is occurring across the pump. Verify that pump #2 does not have excessive wear.