FANUC Alarm PAIN-495 — WARN Non-increasing cal table
Manufacturer wording — WARN (%s) Non-increasing cal table
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PAIN-495 (“WARN Non-increasing cal table”): The IPC auto calibration aborted because the calibration table is not increasing with the commanded flow rate. First check: Ensure pumps are operating correctly.
Updated 2026-09-17 · LogrobotLM reference
Description
The IPC auto calibration aborted because the calibration table is not increasing with the commanded flow rate.
Remedy
Ensure pumps are operating correctly. Ensure that the speed command delay (used to allow the motor RPM to settle) is set to a sufficient amount.