FANUC Alarm PAIN-506 — WARN %sCal. low flow rate reset
Description
This is a warning not a failure. During AccuAir calibration the low flow rate could not be properly reached. A new flow was established. The target flow rate is determined by the Table point no. 2 parameter.
Remedy · Remède
The new flow rate is shown as point 2 in the calibration table. This value can be visually checked and accepted. Increase the yield of the system by increasing air line diameters to the applicator. The Table point no. 2 parameter can be increased (by about 100%).
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.