FANUC Alarm PAIN-582 — WARN … flow command warning
Manufacturer wording — WARN %s flow command warning
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PAIN-582 (“WARN … flow command warning”): During production, an increase in command output was issued in order to maintain setpoint. First check: This problem may be due to a clogged gun tip or old equipment.
Updated 2026-09-17 · LogrobotLM reference
Description
During production, an increase in command output was issued in order to maintain setpoint. This increase surpassed the Command Warning percentage value. An additional jump in command output may fault the robot
Remedy
This problem may be due to a clogged gun tip or old equipment. Clean the gun tip, check the lines, and/or equipment.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →