LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

FANUC Alarm PAIN-584PAUS %s0 res flow rate T.O.

FANUC PAIN-584 (“PAUS %s0 res flow rate T.O.”): All of the conditions were set for resin fluid to be flowing and a zero flow rate was measured. First check: Check that the gun is properly triggering. Likely part: Fluid flow meter (Fluid flow meter).

Updated 2026-08-29 · LogrobotLM reference

Description

All of the conditions were set for resin fluid to be flowing and a zero flow rate was measured. This may be d by: a broken applicator trigger, a loss of resin fluid supply pressure, a broken flow meter, a broken cable (to the flow meter), or a Zero fluid flow timeout value that is too short. Note, Accuchop automatically faults the robot when this alarm occurs.

Remedy · Remède

Check that the gun is properly triggering. If fluid was observed to be flowing, check and possibly replace the fluid flow meter. Possibly increase the Zero flow timeout parameter (by about 25%).

Part to check / replace · Pièce à contrôler / remplacer

FANUC PAIN-584 points to the hardware below — start here before ordering. · PAIN-584 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does FANUC alarm PAIN-584 mean?
FANUC PAIN-584 (“PAUS %s0 res flow rate T.O.”): All of the conditions were set for resin fluid to be flowing and a zero flow rate was measured. This may be d by: a broken applicator trigger, a loss of resin fluid supply pressure, a broken flow meter, a broken cable (to the flow meter), or a Zero fluid flow timeout…
How do you troubleshoot FANUC alarm PAIN-584?
Check that the gun is properly triggering. If fluid was observed to be flowing, check and possibly replace the fluid flow meter. Possibly increase the Zero flow timeout parameter (by about 25%).
Which part is involved in FANUC PAIN-584?
PAIN-584 points to Fluid flow meter (Fluid flow meter). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Same hardware involved / Même matériel en cause

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →