FANUC Alarm PALL-179 — GETINF.TP not setup correctly

FANUC PALL-179 (“GETINF.TP not setup correctly”): GETINF.TP returned an infeed number which is assigned ul = 0. First check: Check GETINF.TP for infeed/unitload data.

Updated 2026-09-17 · LogrobotLM reference

Description

GETINF.TP returned an infeed number which is assigned ul = 0. In other words, PalletTool received an invalid infeed number, most likely 0 from GETINF.TP.

Remedy

Check GETINF.TP for infeed/unitload data. Check production setup data. GETINF.TP is used to return an infeed number for the current cycle. You should modify this program if more than one infeed brought the same unitload to the workcell. In this case, you have to tell PalletTool which infeed to pickup a unit from when both the infeeds have units present. There is an error in the logic of GETINF.TP. Alternatively, you might have provided incorrect assignments at the Cycle Start menu.