FANUC Alarm PNT1-130 — Data Error (see FR:dterrors.ls)
FANUC PNT1-130 (“Data Error (see FR:dterrors.ls)”): The I/O Auto Configurator data file contains errors. First check: Press MENUS and select File.
Updated 2026-09-17 · LogrobotLM reference
Description
The I/O Auto Configurator data file contains errors.
Remedy
Press MENUS and select File. Display FR:dterrors.ls for a description of the error with the corresponding line number.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →