FANUC Alarm PNT1-182 — Canister Position Increasing
FANUC PNT1-182 (“Canister Position Increasing”): This alarm will be displayed if the piston moves during a color change cycle when it is held at the bottom of the can for cleaning, and the cleaning solvent and air pressure overcome the piston air pressure. First check: Perform a scale calibration to insure that the calculated value for the Can Empty Check Counts is valid.
Updated 2026-09-17 · LogrobotLM reference
Description
This alarm will be displayed if the piston moves during a color change cycle when it is held at the bottom of the can for cleaning, and the cleaning solvent and air pressure overcome the piston air pressure.
Remedy
Perform a scale calibration to insure that the calculated value for the Can Empty Check Counts is valid. Increase the Fill Error Tolerance. Verify that the piston pressure is not being restricted.