FANUC Alarm PNT1-515 — %sColor Valve + PrgSol both ON
Description
For integral color change systems, during the execution of a color change cycle, the color enable output and the Purge Solvent output are not allowed to be on at the same time. If the color change cycles attempt to do this, the cycle is aborted. (This is to prevent contamination of the paint lines.)
Remedy · Remède
Check the cycle data table and make sure the color enable and Purge Solvent outputs are never on at the same time.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.