FANUC Alarm PNT1-597 — Max. output has flow < setpoint
Manufacturer wording — %sMax. output has flow < setpoint
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PNT1-597 (“Max. output has flow < setpoint”): With a maximum control output the flow rate was measured to be lower than the setpoint (requested flow). First check: Check the following:
Updated 2026-09-17 · LogrobotLM reference
Description
With a maximum control output the flow rate was measured to be lower than the setpoint (requested flow). This can be caused by:
Remedy
Check the following:
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →