FANUC Alarm PNT1-618%sCal. low flow rate reset

FANUC PNT1-618 (“%sCal. low flow rate reset”): This is a warning not a failure. First check: The new flow rate is shown as point 2 in the calibration table.

Updated 2026-08-29 · LogrobotLM reference

Description

This is a warning not a failure. During AccuAir calibration the low flow rate could not be properly reached. A new flow rate was established. The target flow rate is determined by the Table point no. 2 parameter.

Remedy · Remède

The new flow rate is shown as point 2 in the calibration table. This value can be visually checked and accepted. Increase the yield of the system by increasing air line diameters to the applicator. The Table point no. 2 parameter can be increased (by about 100%).

Frequently asked · Questions fréquentes

What does FANUC alarm PNT1-618 mean?
FANUC PNT1-618 (“%sCal. low flow rate reset”): This is a warning not a failure. During AccuAir calibration the low flow rate could not be properly reached. A new flow rate was established. The target flow rate is determined by the Table point no. 2 parameter.
How do you troubleshoot FANUC alarm PNT1-618?
The new flow rate is shown as point 2 in the calibration table. This value can be visually checked and accepted. Increase the yield of the system by increasing air line diameters to the applicator. The Table point no. 2 parameter can be increased (by about 100%).

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →