FANUC Alarm PNT1-628 — %sRequested flow above cal. table
FANUC PNT1-628 (“%sRequested flow above cal. table”): The requested air flow setpoint is above the calibrated range for Fan Air. First check: Adjust the air flow setpoint to be within the calibrated range of this parameter.
Updated 2026-08-29 · LogrobotLM reference
Description
The requested air flow setpoint is above the calibrated range for Fan Air. The maximum value is shown as point number 10 in the calibration table.
Remedy · Remède
Adjust the air flow setpoint to be within the calibrated range of this parameter. Perform the necessary steps to increase the maximum flow obtained during calibration. This might involve increasing the diameter of the air lines supplying Fan air to the applicator, or changing the type of air booster being used.
Frequently asked · Questions fréquentes
- What does FANUC alarm PNT1-628 mean?
- FANUC PNT1-628 (“%sRequested flow above cal. table”): The requested air flow setpoint is above the calibrated range for Fan Air. The maximum value is shown as point number 10 in the calibration table.
- How do you troubleshoot FANUC alarm PNT1-628?
- Adjust the air flow setpoint to be within the calibrated range of this parameter. Perform the necessary steps to increase the maximum flow obtained during calibration. This might involve increasing the diameter of the air lines supplying Fan air to the applicator, or changing the type of air booster being used.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →