FANUC Alarm PNT1-628 — Requested flow above cal. table

Manufacturer wording — %sRequested flow above cal. table
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT1-628 (“Requested flow above cal. table”): The requested air flow setpoint is above the calibrated range for Fan Air. First check: Adjust the air flow setpoint to be within the calibrated range of this parameter.

Updated 2026-09-17 · LogrobotLM reference

Description

The requested air flow setpoint is above the calibrated range for Fan Air. The maximum value is shown as point number 10 in the calibration table.

Remedy

Adjust the air flow setpoint to be within the calibrated range of this parameter. Perform the necessary steps to increase the maximum flow obtained during calibration. This might involve increasing the diameter of the air lines supplying Fan air to the applicator, or changing the type of air booster being used.