LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm PNT1-832 — PNT1-832

Manufacturer wording — %s
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT1-832 (“PNT1-832”): An attempt was made to extend or retract the valve at SpeedDock side A or B, but failed. First check: Check the retract or extend sensor at SpeedDock side A or B.

Updated 2026-09-17 · LogrobotLM reference

Description

An attempt was made to extend or retract the valve at SpeedDock side A or B, but failed.

Remedy

Check the retract or extend sensor at SpeedDock side A or B. If it was an extended fault, ensure that the pusher extended fully at the Speed Dock side A or B. If it was a retracted fault, ensure that the pusher retracted fully at SpeedDock side A or B and that the valve is not stuck in the extended state. Ensure that sufficient air pressure is available for this operation and that the air lines are connected.

Related codes