FANUC Alarm PNT2-186 — Scale Calibration Aborted
FANUC PNT2-186 (“Scale Calibration Aborted”): The scale calibration sequence did not complete. First check: Check the alarm log to see what conditions caused the calibration to abort.
Updated 2026-09-17 · LogrobotLM reference
Description
The scale calibration sequence did not complete. This can be caused by a timeout or fill/empty error.
Remedy
Check the alarm log to see what conditions caused the calibration to abort. In most cases, the scale cal can timeout from one of the following alarms: PNT1-253 Beaker timeout, scale cal abort, PNT1-248, CC abort, can full timeout, PNT1-249 CC abort, can empty timeout. Verify all equipment is operating properly.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →