FANUC Alarm PNT2-225 — Data Monitor is disabled
FANUC PNT2-225 (“Data Monitor is disabled”): The Data Monitor subsystem has been disabled, by user choice or automatically because limit on data files set by the user has been reached. First check: Enable Data Monitor Operation from the Utilities-Data Monitor screen.
Updated 2026-09-17 · LogrobotLM reference
Description
The Data Monitor subsystem has been disabled, by user choice or automatically because limit on data files set by the user has been reached.
Remedy
Enable Data Monitor Operation from the Utilities-Data Monitor screen. On the Setup-Diagnostics screen, consider increasing Max Data Files Stored or setting Disable After Max Files to NO, if these settings caused Data Monitor to be disabled. See the FANUC PaintTool Operator's Manual, Advanced Functions chapter for more information.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →