FANUC Alarm PNT2-560 — Cal. low flow rate reset
Manufacturer wording — %sCal. low flow rate reset
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PNT2-560 (“Cal. low flow rate reset”): During Accuflow calibration the low flow rate could not be reached. First check: Possibly decrease the Gain modifier used for the color.
Updated 2026-09-17 · LogrobotLM reference
Description
During Accuflow calibration the low flow rate could not be reached. A new low flow rate was established.
Remedy
Possibly decrease the Gain modifier used for the color. The new low flow rate is shown as point 2 in the calibration table. This value can be visually checked and accepted.