FANUC Alarm PNT2-566 — Time out during a cal. test
Manufacturer wording — %sTime out during a cal. test
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PNT2-566 (“Time out during a cal. test”): While measuring hysteresis, time up, or time down the Accuflow system timed out. First check: Retry the calibration.
Updated 2026-09-17 · LogrobotLM reference
Description
While measuring hysteresis, time up, or time down the Accuflow system timed out. This indicates the high or low flow rate could not be reached.
Remedy
Retry the calibration. Check that the high flow rate can be reached consistently. If not an increase in the Tolerance band might be required.