FANUC PNT2-567 (“%sMin. output has flow > setpoint”): With a minimum control output the flow rate was measured to be higher than the setpoint (requested flow). First check: Calibrating the color will establish a new cracking pressure (minimum control output) for a changed fluid pressure. Likely part: Transducer (Transducer) +1 more.
Updated 2026-08-29 · LogrobotLM reference
Description
With a minimum control output the flow rate was measured to be higher than the setpoint (requested flow). The fluid pressure might have become too high. The I/P transducer or fluid regulator might be stuck open. There might be a fairly large fluid leak. Note, Accuflow automatically changes to Open Loop when this failure occurs.
Remedy · Remède
Calibrating the color will establish a new cracking pressure (minimum control output) for a changed fluid pressure. Check and replace if necessary the fluid regulator and I/P transducer. See the Fluid flow leak alarms for other options.
Part to check / replace · Pièce à contrôler / remplacer
FANUC PNT2-567 points to the hardware below — start here before ordering. · PNT2-567 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does FANUC alarm PNT2-567 mean?
- FANUC PNT2-567 (“%sMin. output has flow > setpoint”): With a minimum control output the flow rate was measured to be higher than the setpoint (requested flow). The fluid pressure might have become too high. The I/P transducer or fluid regulator might be stuck open. There might be a fairly large fluid leak. Note,…
- How do you troubleshoot FANUC alarm PNT2-567?
- Calibrating the color will establish a new cracking pressure (minimum control output) for a changed fluid pressure. Check and replace if necessary the fluid regulator and I/P transducer. See the Fluid flow leak alarms for other options.
- Which part is involved in FANUC PNT2-567?
- PNT2-567 points to Transducer (Transducer), Fluid regulator (Fluid regulator). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Same hardware involved / Même matériel en cause
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →