FANUC Alarm PNT2-590%sCal. max. flow rate reset

Description

During Accuflow calibration, the expected maximum flow rate could not be reached at the maximum output. A new maximum flow was established.

Remedy · Remède

Possibly decrease the Gain modifier used for the color. The new maximum flow rate is shown as point 10 in the calibration table. This value can be visually checked and accepted.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.