FANUC Alarm PNT2-592 — %sCal. time out at low flow
FANUC PNT2-592 (“%sCal. time out at low flow”): Accuflow timed out trying to reach the loweset flow rate, typically 100 cc/min. First check: Possibly decrease the Gain modifier used for the color. Likely part: Fluid regulator (Fluid regulator).
Updated 2026-08-29 · LogrobotLM reference
Description
Accuflow timed out trying to reach the loweset flow rate, typically 100 cc/min. Possible causes are: a high gain, a sticking I/P transducer, a bad fluid regulator or frequent fluid pressure changes.
Remedy · Remède
Possibly decrease the Gain modifier used for the color. Retry the calibration. Check and change the transducer if necessary, replace the fluid regulator or service the surge suppression system on the fluid supply pump. The calibration timeout parameter can be increased.
Part to check / replace · Pièce à contrôler / remplacer
FANUC PNT2-592 points to the hardware below — start here before ordering. · PNT2-592 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does FANUC alarm PNT2-592 mean?
- FANUC PNT2-592 (“%sCal. time out at low flow”): Accuflow timed out trying to reach the loweset flow rate, typically 100 cc/min. Possible causes are: a high gain, a sticking I/P transducer, a bad fluid regulator or frequent fluid pressure changes.
- How do you troubleshoot FANUC alarm PNT2-592?
- Possibly decrease the Gain modifier used for the color. Retry the calibration. Check and change the transducer if necessary, replace the fluid regulator or service the surge suppression system on the fluid supply pump. The calibration timeout parameter can be increased.
- Which part is involved in FANUC PNT2-592?
- PNT2-592 points to Fluid regulator (Fluid regulator). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Same hardware involved / Même matériel en cause
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →