FANUC Alarm PNT2-622 — 0 air flow rate detected

Manufacturer wording — %s0 air flow rate detected
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT2-622 (“0 air flow rate detected”): All of the conditions were set for air to be flowing and a zero flow rate was measured. First check: Check, clean and possibly replace the air cap. Likely part: Air flow sensor (Air flow sensor) +1 more.

Updated 2026-09-17 · LogrobotLM reference

Description

All of the conditions were set for air to be flowing and a zero flow rate was measured. This might be caused by: a broken applicator trigger, pinched air lines, a loss (or near loss) of air supply pressure, a broken air flow sensor, a broken cable (to the flow sensor), or a Trigger delay that is too short. Note, AccuAir temporarily automatically changes to Open Loop when this alarm occurs.

Remedy

Check, clean and possibly replace the air cap. Check that the gun is properly triggering. If air was observed to be flowing check and possibly replace the air flow sensor. Check for a pinched air line. Increase the Trigger delay parameter (by about 50%).

Part to check / replace

FANUC PNT2-622 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.