FANUC Alarm PNT2-628 — Requested flow above cal. table
Manufacturer wording — %sRequested flow above cal. table
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PNT2-628 (“Requested flow above cal. table”): The requested air flow setpoint is above the calibrated range for Fan Air. First check: Adjust the air flow setpoint to be within the calibrated range of this parameter.
Updated 2026-09-17 · LogrobotLM reference
Description
The requested air flow setpoint is above the calibrated range for Fan Air. The maximum value is shown as point number 10 in the calibration table.
Remedy
Adjust the air flow setpoint to be within the calibrated range of this parameter. Perform the necessary steps to increase the maximum flow obtained during calibration. This might involve increasing the diameter of the air lines supplying Fan air to the applicator or changing the type of air booster used.