FANUC Alarm PNT2-632%s0 air flow rate timeout

FANUC PNT2-632 (“%s0 air flow rate timeout”): All of the conditions were set for air to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. First check: Check, clean and possibly replace the air cap. Likely part: Air flow sensor (Air flow sensor) +1 more.

Updated 2026-08-29 · LogrobotLM reference

Description

All of the conditions were set for air to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. This may be caused by: a clogged air cap, a broken applicator trigger, broken air lines, a loss of air supply pressure, a broken air flow sensor, a broken cable (to the flow sensor), or a Zero flow timeout value that is too short. Note, AccuAir temporarily automatically changes to Open Loop when this alarm occurs.

Remedy · Remède

Check, clean and possibly replace the air cap. Check that the gun is properly triggering. If air was observed to be flowing, check and possibly replace the air flow sensor. Check for a broken air line. Possibly increase the Zero flow timeout parameter (by about 25%).

Part to check / replace · Pièce à contrôler / remplacer

FANUC PNT2-632 points to the hardware below — start here before ordering. · PNT2-632 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does FANUC alarm PNT2-632 mean?
FANUC PNT2-632 (“%s0 air flow rate timeout”): All of the conditions were set for air to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. This may be caused by: a clogged air cap, a broken applicator trigger, broken air lines, a loss of air supply pressure, a broken air…
How do you troubleshoot FANUC alarm PNT2-632?
Check, clean and possibly replace the air cap. Check that the gun is properly triggering. If air was observed to be flowing, check and possibly replace the air flow sensor. Check for a broken air line. Possibly increase the Zero flow timeout parameter (by about 25%).
Which part is involved in FANUC PNT2-632?
PNT2-632 points to Air flow sensor (Air flow sensor), Air cap (Air cap (paint atomizer)). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Same hardware involved / Même matériel en cause

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →