FANUC Alarm PNT2-634 — Dyn. yield > min tolerance band

Manufacturer wording — %sDyn. yield > min tolerance band
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT2-634 (“Dyn. yield > min tolerance band”): As a particular flow rate set point is being output the yield (slpm/cnt) for that flow rate was approximately larger than the percent tolerance. First check: Decrease the yield.

Updated 2026-09-17 · LogrobotLM reference

Description

As a particular flow rate set point is being output the yield (slpm/cnt) for that flow rate was approximately larger than the percent tolerance. It is not likely that the set point will be reached within the specified tolerances. This might be caused by the use of a flow rate setpoint that is below the value that the air system can accurately provide.

Remedy

Decrease the yield. Use larger diameter air lines to supply air to the cap. Use a smaller ratio booster. Otherwise, accept a larger tolerance band. Increase the minimum tolerance (by about 50%).