FANUC Alarm PNT2-768 — (%s) Non-increasing cal table
FANUC PNT2-768 (“(%s) Non-increasing cal table”): The IPC auto calibration aborted because the calibration table is not increasing with the commanded flow rate. First check: Ensure pumps are operating correctly.
Updated 2026-08-29 · LogrobotLM reference
Description
The IPC auto calibration aborted because the calibration table is not increasing with the commanded flow rate.
Remedy · Remède
Ensure pumps are operating correctly. Ensure that the speed command delay (used to allow the motor RPM to settle) is set to a sufficient amount.
Frequently asked · Questions fréquentes
- What does FANUC alarm PNT2-768 mean?
- FANUC PNT2-768 (“(%s) Non-increasing cal table”): The IPC auto calibration aborted because the calibration table is not increasing with the commanded flow rate.
- How do you troubleshoot FANUC alarm PNT2-768?
- Ensure pumps are operating correctly. Ensure that the speed command delay (used to allow the motor RPM to settle) is set to a sufficient amount.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →