FANUC Alarm PNT2-807 — Pump 2 fluid flow rate < set point

Manufacturer wording — %sPump 2 fluid flow rate < set point
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT2-807 (“Pump 2 fluid flow rate < set point”): The actual flow rate out of pump #2 as measured by the fluid flow meter has been continuously less than a set point window (a percentage) for a user configurable period of time. First check: Do a fluid flow test on pump #2 with a beaker and verify that the beaker amount matches the pump #2 size (cc/rev).

Updated 2026-09-17 · LogrobotLM reference

Description

The actual flow rate out of pump #2 as measured by the fluid flow meter has been continuously less than a set point window (a percentage) for a user configurable period of time.

Remedy

Do a fluid flow test on pump #2 with a beaker and verify that the beaker amount matches the pump #2 size (cc/rev). Verify that the correct KFT factor has been entered for the fluid flow meter per the manufacturers specification. Check the operation of the inlet regulator to verify that no (blow by) is occurring across the pump.