FANUC Alarm PRIO-104 — STOP Device is off-line
Description
An attempt has been made to access to a port assigned to a device or board which is offline. This might be the result of an error or device having been set offline manually.
Remedy · Remède
For DeviceNet ports, troubleshoot as follows: Check the status of the DeviceNet board using the Digital I/O DeviceNet screen. If the status field for the board is OFF, set it ONLINE. If the status is ERROR, check the following: 1.) The daughter board is installed on the Interface board. 2.) There is power on the network. If these do not indicate a problem, set the board ONLINE. If the board is ONLINE, check the DEV LST screen entry for the indicated device. If the status field for the device is OFF, set it ONLINE. If the status is ERROR, check the following: 1. The device is physically present on the network. 2. The baud rate is set correctly. 3. There are not devices with duplicate MAC-Id's on the network. 4. The device with the required MAC-Id is the device type indicated in the DEV LST screen.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.