FANUC Alarm PRIO-165 — WARN CNET Connection Not Found

FANUC PRIO-165 (“WARN CNET Connection Not Found”): The interface could not establish a connection as it was not found. First check: Verify the scan-list configuration and match it with the target device.

Updated 2026-09-17 · LogrobotLM reference

Description

The interface could not establish a connection as it was not found.

Remedy

Verify the scan-list configuration and match it with the target device. Verify the connection paths. The connection path expected by the scan- list can be found in the EDS file for the target device. The connection path supported by the target device can be found in its documentation. Verify that the target device and the EDS file used by the Scanner config match.

Related codes