FANUC Alarm PRIO-225 — EGD Consumer timeout - Id:…
Manufacturer wording — EGD Consumer timeout - Id:%d
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PRIO-225 (“EGD Consumer timeout - Id:…”): The EGD Consumer timed-out while waiting for an I/O message from an EGD Producer. First check: Press RESET to clear the error.
Updated 2026-09-17 · LogrobotLM reference
Description
The EGD Consumer timed-out while waiting for an I/O message from an EGD Producer.
Remedy
Press RESET to clear the error. Check the EGD Producer device to verify that it is functioning properly. Check the EGD Consumer timeout value. Typically, the EGD timeout value should be three times the EGD Producer's interval. Refer to the Ethernet Global Data Operator's Manual for more information.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →