FANUC Alarm SEAL-180 — WARN EOAT timed out: Retract

FANUC SEAL-180 (“WARN EOAT timed out: Retract”): The Four Position End of Arm tool was moved, but the RETRACT sensor reports that the tool is not in the correct RETRACT/EXTEND position (could be ON or OFF) after the timeout period set on the tool setup menu expired. First check: Check air supply to the four position tool.

Updated 2026-09-17 · LogrobotLM reference

Description

The Four Position End of Arm tool was moved, but the RETRACT sensor reports that the tool is not in the correct RETRACT/EXTEND position (could be ON or OFF) after the timeout period set on the tool setup menu expired.

Remedy

Check air supply to the four position tool. Check proximity sensors on the four position tool. If the tool is slow, increase the timeout delay on the tool setup screen to allow enough time for the tool to complete motion.