FANUC Alarm SEAL-283 — WARN Both Meters Empty

FANUC SEAL-283 (“WARN Both Meters Empty”): This warning is posted when the system detects that both meters have reached to their stroke limit during dispensing. First check: 1. Increase the material supply pressure.

Updated 2026-09-17 · LogrobotLM reference

Description

This warning is posted when the system detects that both meters have reached to their stroke limit during dispensing. This situation occurs if the material supply pressure is too low. After this condition, the system automatically stops dispensing, but the robot keeps moving. Use Error table to change the severity to PAUSE if you want to pause the program with this warning.

Remedy

1. Increase the material supply pressure. 2. Lower the flow rate.

Related codes