FANUC Alarm SEAL-292 — STOP Max Error table entry exceeded
FANUC SEAL-292 (“STOP Max Error table entry exceeded”): In setting up the Default error table the maximum number of error table entries ($ERRSEV_NUM) was exceeded. First check: Go into controlled start, Press MENU-0, then choose PROGRAM SETUP.
Updated 2026-09-17 · LogrobotLM reference
Description
In setting up the Default error table the maximum number of error table entries ($ERRSEV_NUM) was exceeded.
Remedy
Go into controlled start, Press MENU-0, then choose PROGRAM SETUP. Change the Error Severity Table entry to be a larger number in order to contain all default errors, and press FCTN-START (COLD). After Cold Start, go back into the Error Table setup screen and manually enter in those error that were not setup correctly.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →