LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

FANUC Alarm SPOT-001PAUSE Backup not closed %s

FANUC SPOT-001 (“PAUSE Backup not closed %s”): BU=* was specified in the SPOT instruction for backup state before the weld, but the backup was opened at the time the instruction was executed. First check: Make sure that the backup is closed when using the BU=* command.

Updated 2026-08-29 · LogrobotLM reference

Description

BU=* was specified in the SPOT instruction for backup state before the weld, but the backup was opened at the time the instruction was executed.

Remedy · Remède

Make sure that the backup is closed when using the BU=* command. Edit the BU=* to BU=C, or insert a BACKUP=CLOSE statement prior to this statement.

Frequently asked · Questions fréquentes

What does FANUC alarm SPOT-001 mean?
FANUC SPOT-001 (“PAUSE Backup not closed %s”): BU=* was specified in the SPOT instruction for backup state before the weld, but the backup was opened at the time the instruction was executed.
How do you troubleshoot FANUC alarm SPOT-001?
Make sure that the backup is closed when using the BU=* command. Edit the BU=* to BU=C, or insert a BACKUP=CLOSE statement prior to this statement.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →