FANUC Alarm SPOT-002 — PAUSE Iso contactor fault %s
FANUC SPOT-002 (“PAUSE Iso contactor fault %s”): The isolation contactor on the specified weld controller is in a fault condition. First check: Make sure that the CLOSE CONTACTOR macro instruction has been programmed in the teach pendant program.
Updated 2026-08-29 · LogrobotLM reference
Description
The isolation contactor on the specified weld controller is in a fault condition. If no program is running, then this message is posted if either the Iso contactor output is high or the Iso contactor input is high. If a program is running, or a manual weld is being executed, then the output, if defined, must be high, and the input, if defined, must be high too.
Remedy · Remède
Make sure that the CLOSE CONTACTOR macro instruction has been programmed in the teach pendant program.
Frequently asked · Questions fréquentes
- What does FANUC alarm SPOT-002 mean?
- FANUC SPOT-002 (“PAUSE Iso contactor fault %s”): The isolation contactor on the specified weld controller is in a fault condition. If no program is running, then this message is posted if either the Iso contactor output is high or the Iso contactor input is high. If a program is running, or a manual weld is being…
- How do you troubleshoot FANUC alarm SPOT-002?
- Make sure that the CLOSE CONTACTOR macro instruction has been programmed in the teach pendant program.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →