FANUC Alarm SPOT-008 — PAUSE Weld complete timeout …

Manufacturer wording — PAUSE Weld complete timeout %s
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC SPOT-008 (“PAUSE Weld complete timeout …”): The robot timed out waiting for the Weld Complete input from the weld controller. First check: Check the Weld I/O menu, as well as all wiring.

Updated 2026-09-17 · LogrobotLM reference

Description

The robot timed out waiting for the Weld Complete input from the weld controller.

Remedy

Check the Weld I/O menu, as well as all wiring. If the input is going high, try increasing the timeout by setting $spoteqsetup[].$wld_comp_to to a bigger number. The default is 2000 ms, or 2 seconds.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →