LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SPOT-044 — WARN Stud Welder Arc Voltage Fault

FANUC SPOT-044 (“WARN Stud Welder Arc Voltage Fault”): This fault is signaled by the Stud Weld controller if the voltage sensor reports too little arc voltage during the weld process. First check: The stud checker will automaticly verify the quality of the weld.

Updated 2026-09-17 · LogrobotLM reference

Description

This fault is signaled by the Stud Weld controller if the voltage sensor reports too little arc voltage during the weld process. May result in a poor quality weld.

Remedy

The stud checker will automaticly verify the quality of the weld. If bad, check the position of the gun at the weld spot to insure that the tip is the correct distance.

Related codes